J. Mater. Sci. Technol. ›› 2024, Vol. 196: 101-111.DOI: 10.1016/j.jmst.2024.01.047

• Reserch Article • Previous Articles     Next Articles

Comparative study of flame retardancy in polyimine vitrimers and composites: Evaluating additive and reactive flame retardants acting via gas-, solid-, and combined-phase mechanisms

Andrea Toldya,b,*, Dániel István Poórc,b, Beáta Szolnokid, Boglárka Devecsera, Norbert Geierc, Ákos Pomázie,a,b   

  1. aDepartment of Polymer Engineering, Faculty of Mechanical Engineering, Budapest University of Technology and Economics, H-1111 Budapest, Műegyetem rkp. 3, Hungary;
    bMTA-BME Lendület Sustainable Polymers Research Group, Műegyetem rkp. 3, H-1111 Budapest, Hungary;
    cBudapest University of Technology and Economics, Faculty of Mechanical Engineering, Department of Manufacturing Science and Engineering, Műegyetem rkp. 3., Budapest 1111, Hungary;
    dDepartment of Organic Chemistry and Technology, Faculty of Chemical Technology and Biotechnology, Budapest University of Technology and Economics, H-1111 Budapest, Műegyetem rkp. 3, Hungary;
    eHUN-REN-BME Research Group for Composite Science and Technology, Műegyetem rkp. 3., H-1111 Budapest, Hungary
  • Received:2023-10-31 Revised:2023-12-20 Accepted:2024-01-08 Published:2024-10-10 Online:2024-03-11
  • Contact: * E-mail address: atoldy@edu.bme.hu (A. Toldy).

Abstract: We developed flame retarded polyimine type vitrimers and carbon fibre reinforced composites using two additive and a reactive flame retardant containing phosphorus: ammonium polyphosphate (APP), resorcinol bis(diphenyl phosphate) (RDP); and N,N',N''-tris(2-aminoethyl)-phosphoric acid triamide (TEDAP). We characterised the vitrimer matrix materials by differential scanning calorimetry (DSC), thermal analysis (TGA), limiting oxygen index (LOI), UL-94 test and mass loss calorimetry (MLC), while the vitrimer composites by LOI, UL-94 test, MLC and dynamic mechanical analysis (DMA). We compared the performance of the vitrimer systems to a benchmark pentaerythritol-based aliphatic epoxy resin system (PER). The vitrimer reference had higher thermal stability but lower fire performance than the PER aliphatic reference epoxy. At lower phosphorus content, the vitrimer systems exhibited a melting above their vitrimer transition temperature, which negatively affected their LOI and UL-94 results. From 2% phosphorus content, rapid charring and extinguishing of vitrimers prevented the softening and deforming. The superior performance of these same flame retardants in vitrimer systems could be attributed to the high nitrogen content of imine-based vitrimers in combination with phosphorus flame retardants, exploiting nitrogen-phosphorus synergism. In both matrices, flame retardants with solid phase action lead to better fire performance, while in composites, the lowest peak heat release rates (152 kW/m2 in vitrimer composite) were achieved with RDP acting predominantly in the gas phase, as carbon fibres hindered the intumescent phenomenon.